Top level hotsell BAC cooling tower fill
-
USD0.11-0 Piece/Pieces
-
USD0.9≥1 Piece/Pieces
- Incoterm:
- FOB
- Min. Order:
- 1 Piece/Pieces
- Min. Order:
- 1 Piece/Pieces
- Delivery Time:
- 19 Days
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | China |
---|---|
Productivity: | 10000pcs/day |
Supply Ability: | 10000pcs/week |
Incoterm: | FOB |
Certificate: | ISO QC |
BAC Cooling tower fill:
- equivalent to BAC Cooling tower fills
- Virgin, high density, Enviromental, safe PVC material.
- 1330mm width, Any length,
- One week for 4000pcs production, quickly delivery
BAC Cooling tower material introduction:
BAC cooling Tower Fill is one of the most important components for exchange of gas and water in cooling tower. It is the major parts to improve the efficiency of cooling tower and make sure the economy and safe operation. With the development of the plastic industry, counter-current tower drench water plastic packing "S" shape ladder wave, obliquely wave, which has the heat dissipation ,good performance ,Ventilated small resistance, durable, based on the easy and other advantages, it is widely used in different types of large, medium, small, cooling tower.
BAC fill features:
1. Improved water distribution
2. High thermal performance
3. Material meets Cooling Tower Institute
4.Mainly apply to Counterflow fill.
Size: Any length*1330 width
Thickness:0.35-0.45mm
Application temperature: 75°C~35°C
Tensile StrengthMPa 23°C:55
Coefficient of heat conductivity(W/MK):0.14
Coefficient of themal expansion(<X10¯4K¯¹>):0.63
BAC Evaporative condensers provide heat rejection for many types of systems, and the specific application will largely determine which BAC Evaporative Condenser is best suited for a project. The information contained within this section is geared towards the use of evaporative condensers in the HVAC and light industrial markets only. Evaporative condensers are used in these markets to provide lower condensing temperatures and compressor horsepower savings of up to 15 percent when compared with traditional systems.
Principle of Operation
The vapor to be condensed is circulated through a condensing coil, which is continually wetted on the outside by a recirculating water system. Air is pulled over the coil, causing a small portion of the recirculating water to evaporate. The evaporation removes heat from the vapor in the coil, causing it to condense.
Configuration
BAC manufactures two types of evaporative condensers: combined flow and counterflow.
Combined Flow
Combined flow is the use of both a condensing coil and fill surface for heat transfer in an evaporative condenser. The addition of fill surface to the traditional evaporative condenser design reduces evaporation in the coil section, reducing the potential for scaling and fouling. BAC`s combined flow evaporative condensers utilize parallel flow of air and spray water over the coil, and crossflow air/water flow through the fill surface.
In parallel flow, air and water flow over the coil in the same direction. In the fill section of BAC`s combined flow evaporative condensers, air and water interact in a crossflow configuration: water flows vertically down the fill as air flows horizontally across it.