LV 0.6/1KV 3 core XLPE electric cable size:3x95mm2
- Delivery Time:
- 35 Days
Quantity:
Your message must be between 20 to 2000 characters
Contact NowBasic Info
Basic Info
Place of Origin: | Hebei, China (Mainland) |
---|
Product Description
Product Description
Specifications 3 core electric power cable
1.size:3x95mm2
2.voltage:8.7/10kv
3.insulation material:XLPE
1). Application:
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
Standards / Testing Specications: IEC 60502-1.
2). Description:
-Conductor: Solid or stranded copper
-Insulation: Cross-linked polyethylene XLPE
-Circuit Identification: The insulation shall be red, black or others
-Filler: Polypropylene lament with lapped binding tape
-Inner Sheath: LSZH (Black)
-Armor: Galvanized steel wire
-Core-covering: Binding tape
-Outer Sheath: LSZH (Black)
3). Brief Construction & Using :
Single core or multi-core
Copper or aluminium conductor
XLPE insulation
Copper tape or wire screen
Galvanized steel wire armored
PVC sheath a). The products are mainly complying with IEC60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
b). Cross-section area can be up to 800 sqmm (copper or aluminum conductor).
c). Conductor long-time operating temperature is 90 degrees. In short circuit
d). Conductor highest temperature should be not more than 250 degrees. e). The cables can be laid without the limit of fall with enough mechanical pull, but the single core cable can't be laid in iron tube or can't be fixed by circled iron tools around the cables.
f). The laying temperature of cables should not be lower than 0 degree, when the ambient temperature is under 0 degree, the cables should be heated up to 0 degree higher with certain methods. 4.)Structure info:
5.Product pictures:

1.size:3x95mm2
2.voltage:8.7/10kv
3.insulation material:XLPE
1). Application:
For use in ducts, trays and direct burial in ground. The cable is subject to immerse in water all the time.
Standards / Testing Specications: IEC 60502-1.
2). Description:
-Conductor: Solid or stranded copper
-Insulation: Cross-linked polyethylene XLPE
-Circuit Identification: The insulation shall be red, black or others
-Filler: Polypropylene lament with lapped binding tape
-Inner Sheath: LSZH (Black)
-Armor: Galvanized steel wire
-Core-covering: Binding tape
-Outer Sheath: LSZH (Black)
3). Brief Construction & Using :
Single core or multi-core
Copper or aluminium conductor
XLPE insulation
Copper tape or wire screen
Galvanized steel wire armored
PVC sheath a). The products are mainly complying with IEC60502 standard, also can be produced according to OEM requirements and other standards, such as BS standard, DIN standard, ASTM standard, etc.
b). Cross-section area can be up to 800 sqmm (copper or aluminum conductor).
c). Conductor long-time operating temperature is 90 degrees. In short circuit
d). Conductor highest temperature should be not more than 250 degrees. e). The cables can be laid without the limit of fall with enough mechanical pull, but the single core cable can't be laid in iron tube or can't be fixed by circled iron tools around the cables.
f). The laying temperature of cables should not be lower than 0 degree, when the ambient temperature is under 0 degree, the cables should be heated up to 0 degree higher with certain methods. 4.)Structure info: